CODE TITLE | PVH | VICKERS PRESSURE COMPENSATED/PRESSURE FLOW COMPENSATED OPEN CIRCUIT PISTON PUMP |
DISPLACEMENT | 057 | 57,4 CM3/R [3.50 IN3/R] |
INPUT SHAFT ROTATION | R | RIGHT-HAND ROTATION (CW) RIGHT SIDE SUCTION PORT, LEFT SIDE PRESSURE PORT |
FRONT MOUNTING & INPUT SHAFT | 01 | 4 BOLT C (SAE J744-127-4) WITH 31.8 [1.25] DIA STRAIGHT KEYED SHAFT (KEY INCLUDED), 56.0 [2.20] SHAFT EXTENSION |
MAIN PORTS SIZE & LOCATION | AA | SIDE PORTS; SUCTION - 2.000 SAE 4-BOLT SPLIT FLANGE PORT STANDARD PRESSURE SERIES (CODE 61) WITH 1/2-13 UNC-2B THREADS; PRESSURE - 1.000 SAE 4-BOLT SPLIT FLANGE PORT STANDARD PRESSURE SERIES (CODE 61) WITH 3/8-16 UNC-2B THREADS |
DRAIN PORT SIZE & LOCATION | 1 | .750-16 UNF-2B SAE O-RING PORT - BOTTOM (TOP PLUGGED) |
DIAGNOSTIC PRESSURE PORT | 0 | NO DIAGNOSTIC PRESSURE PORT |
CONTROLLER TYPE | A | PRESSURE COMPENSATOR |
PRESSURE COMPENSATOR SETTING | 25 | 246-254 BAR [3568-3684 LBF/IN2] |
FLOW COMP, IC CONT. / UNLOAD VLV STANDBY | 00 | NO FLOW COMPENSATION SETTING OR UNLOAD VALVE STANDBY |
TORQUE SENSING / OTHER COMPENSATION | 00 | NO TORQUE SENSING SETTING OR OTHER COMPENSATION |
CONTROL SPECIAL FEATURES | 00 | NO CONTROL SPECIAL FEATURES |
MAXIMUM DISPLACEMENT OPTION | 2 | ADJUSTABLE MAXIMUM DISPLACEMENT (SET AT MAXIMUM) |
AUXILIARY MOUNTING & OUTPUT SHAFT | 00 | NO AUXILIARY MOUNTING OR OUTPUT SHAFT |
SHAFT SEALS | 1 | SINGLE, ONE-WAY SHAFT SEAL, FLUOROCARBON |
SPECIAL FEATURES | AE | Q250 VALVE PLATE, NO CASE TO INLET CHECK VALVE |
PAINT | 01 | BLUE PRIMER |
CUSTOMER &/OR UNIT IDENTIFICATION | 0 | NONE - MARK ASSEMBLY NUMBER, COMPLETE MODEL CODE AND BUILD DATE CODE ON PLATE |
DESIGN CODE | A | FIRST DESIGN |