| SIMATIC S7-400H, CPU 417H CENTRAL UNIT FOR S7-400H 4 INTERFACES: 1 MPI/DP, 1 DP A. 2 FOR SYNC MODULES 4MB MEMORY (2MB CODE/2MB DATA) |
Supply voltage |
Rated value (DC) | |
24 V DC | Yes |
Input current |
from backplane bus 5 V DC, typ. | 1.8 A |
from backplane bus 5 V DC, max. | 2 A |
from backplane bus 24 V DC, max. | 300 mA; Total current consumption of the components connected to the MPI/DP interfaces, but no more than 150 mA per interface |
Power loss |
Power loss, typ. | 10 W |
Memory |
Work memory |
integrated | 4 Mbyte |
integrated (for program) | 2 Mbyte |
integrated (for data) | 2 Mbyte |
expandable | Yes |
expandable, max. | 20 Mbyte; up to 10 MB for program, up to 10 MB for data |
Load memory |
expandable FEPROM | Yes; with Memory Card (FEPROM) |
expandable FEPROM, max. | 64 Mbyte |
integrated RAM, max. | 256 kbyte |
expandable RAM | Yes; with Memory Card (RAM) |
expandable RAM, max. | 64 Mbyte |
Backup |
present | Yes |
with battery | Yes; all data |
without battery | No |
Battery |
Backup battery |
Backup current, typ. | 75 µA |
Backup current, max. | 860 µA |
Feeding of external backup voltage to CPU | 5 V DC to 15 V DC |
CPU processing times |
for bit operations, typ. | 0.1 µs |
for word operations, typ. | 0.1 µs |
for fixed point arithmetic, typ. | 0.1 µs |
for floating point arithmetic, typ. | 0.6 µs |
CPU-blocks |
DB |
Number, max. | 8 192; DB 0 reserved |
Size, max. | 64 kbyte |
FB |
Number, max. | 6 144 |
Size, max. | 64 kbyte |
FC |
Number, max. | 6 144 |
Size, max. | 64 kbyte |
OB |
Number, max. | see instruction list |
Size, max. | 64 kbyte |
Counters, timers and their retentivity |
S7 counter |
Number | 512 |
Retentivity |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 2 047 |
— preset | Z 0 to Z 7 |
Counting range |
— lower limit | 1 |
— upper limit | 999 |
IEC counter |
present | Yes |
Type | SFB |
S7 times |
Number | 512 |
Time range |
— lower limit | 10 ms |
— upper limit | 9 990 s |
IEC timer |
present | Yes |
Type | SFB |
Data areas and their retentivity |
Flag |
Number, max. | 16 kbyte |
Retentivity available | Yes; MB 0 to MB 16383 |
Retentivity preset | MB 0 to MB 15 |
Address area |
I/O address area |
Inputs | 16 kbyte |
Outputs | 16 kbyte |
Process image |
Inputs, adjustable | 16 kbyte; adjustable at the expense of the code area of the RAM |
Outputs, adjustable | 16 kbyte; adjustable at the expense of the code area of the RAM |
Inputs, default | 1 024 byte |
Outputs, default | 1 024 byte |
Subprocess images |
Number of subprocess images, max. | 8 |
Digital channels |
Inputs | 131 072 |
— of which central | 131 072 |
Outputs | 131 072 |
— of which central | 131 072 |
Analog channels |
Inputs | 8 192 |
— of which central | 8 192 |
Outputs | 8 192 |
— of which central | 8 192 |
Hardware configuration |
Number of expansion units, max. | 21 |
Multicomputing | No |
Interface modules |
Number of connectable IMs (total), max. | 6 |
Number of connectable IM 460s, max. | 6 |
Number of connectable IM 463s, max. | 6 |
Number of DP masters |
integrated | 2 |
via CP | 10 |
via IM 467 | 0 |
Mixed mode IM + CP permitted | No; IM 467 cannot be used jointly with CP 443-5 Ext. |
via interface module | 0 |
Number of operable FMs and CPs (recommended) |
FM | 64; Limited by number of slots and number of connections |
CP, PtP | 64; Limited by number of slots and number of connections |
CP, LAN | 64; Limited by number of slots and number of connections |
Slots |
required slots | 2 |
Time of day |
Clock |
Hardware clock (real-time) | Yes |
retentive and synchronizable | Yes |
Operating hours counter |
Number | 8 |
Clock synchronization |
supported | Yes |
1. Interface |
Physics | RS 485 / PROFIBUS |
Isolated | Yes |
Protocols |
MPI | Yes; Default setting |
PROFIBUS DP master | Yes |
PROFIBUS DP slave | No |
MPI |
Number of connections | 44 |
Transmission rate, max. | 12 Mbit/s |
Services |
— PG/OP communication | Yes |
— Global data communication | No |
— S7 basic communication | No |
— S7 communication | Yes |
— S7 communication, as client | Yes |
— S7 communication, as server | Yes |
PROFIBUS DP master |
Number of connections, max. | 32; of which 1 reserved for PG, 1 for OP |
Transmission rate, max. | 12 Mbit/s |
Number of DP slaves, max. | 32; Number of slots, max. 512 |
Services |
— PG/OP communication | Yes |
— Global data communication | No |
— S7 basic communication | No |
— S7 communication | No |
— S7 communication, as client | No |
— S7 communication, as server | No |
— Equidistance | No |
— SYNC/FREEZE | No |
— Activation/deactivation of DP slaves | No |
— Direct data exchange (slave-to-slave communication) | No |
Address area |
— Inputs, max. | 2 kbyte |
— Outputs, max. | 2 kbyte |
User data per DP slave |
— Inputs, max. | 244 byte |
— Outputs, max. | 244 byte |
— per slot, max. | 244 byte |
2. Interface |
Physics | RS 485 / PROFIBUS |
Isolated | Yes |
Protocols |
PROFIBUS DP master | Yes |
PROFIBUS DP slave | No |
Point-to-point connection | No |
PROFIBUS DP master |
Number of connections, max. | 16; For PG/OP communication |
Transmission rate, max. | 12 Mbit/s |
Number of DP slaves, max. | 125; Number of slots, max. 2048 |
Services |
— PG/OP communication | Yes |
— Global data communication | No |
— S7 basic communication | No |
— S7 communication | No |
— S7 communication, as client | No |
— S7 communication, as server | No |
— Equidistance | No |
— SYNC/FREEZE | No |
— Activation/deactivation of DP slaves | No |
— Direct data exchange (slave-to-slave communication) | No |
Address area |
— Inputs, max. | 8 kbyte |
— Outputs, max. | 8 kbyte |
User data per DP slave |
— Inputs, max. | 244 byte |
— Outputs, max. | 244 byte |
Communication functions |
PG/OP communication | Yes |
Global data communication |
supported | No |
S7 basic communication |
supported | No |
S7 communication |
supported | Yes |
as server | Yes |
as client | Yes |
User data per job, max. | 64 kbyte |
S5 compatible communication |
supported | Yes; via CP and loadable FC |
User data per job, max. | 8 kbyte |
Standard communication (FMS) |
supported | Yes; Via CP and loadable FB |
User data per job, max. | Dependent on CP |
Number of connections |
overall | 64 |
usable for PG communication | |
— reserved for PG communication | 1 |
— adjustable for PG communication, max. | 0 |
usable for OP communication | |
— reserved for OP communication | 1 |
— adjustable for OP communication, max. | 0 |
usable for S7 basic communication | |
— reserved for S7 basic communication | 0 |
— adjustable for S7 basic communication, max. | 0 |
usable for routing | |
— reserved for routing | 0 |
— adjustable for routing, max. | 0 |
S7 message functions |
Number of login stations for message functions, max. | 16 |
Configuration |
Configuration software |
STEP 7 | Yes; V5.0 SP2 |
Programming |
Programming language |
— LAD | Yes |
— FBD | Yes |
— STL | Yes |
— SCL | Yes |
— CFC | Yes |
— GRAPH | Yes |
— HiGraph® | Yes |
Know-how protection |
User program protection/password protection | Yes |
Dimensions |
Width | 50 mm |
Height | 290 mm |
Depth | 219 mm |
Weights |
Weight, approx. | 1 070 g |
last modified: | 03/13/2019 |