| ***Spare part*** SIMATIC S7-200, Digital I/O EM 223, only for S7-22X CPU, 4 DI/4 DO relay, 5-30 V DC, 250 V AC |
Supply voltage |
Load voltage L+ |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 5 V |
permissible range, upper limit (DC) | 30 V |
Load voltage L1 |
Rated value (AC) | 230 V; 24V AC to 230V AC |
permissible range, lower limit (AC) | 5 V |
permissible range, upper limit (AC) | 250 V |
Input current |
from backplane bus 5 V DC, max. | 40 mA |
from sensor current supply or external current supply (24 V DC), max. | 72 mA |
from coil current, max. | 9 mA; for each output on signal "1" |
Power loss |
Power loss, typ. | 2 W |
Digital inputs |
Number of digital inputs | 4 |
Input voltage |
Type of input voltage | AC/DC |
Rated value (DC) | 24 V |
for signal "0" | 0 to 5 V |
for signal "1" | 15 V DC to 30 V DC |
Input current |
for signal "1", typ. | 4 mA |
Input delay (for rated value of input voltage) |
for standard inputs |
— at "0" to "1", max. | 4.5 ms |
Digital outputs |
Number of digital outputs | 4; Relays |
Short-circuit protection | No |
Output voltage |
for signal "0", max. | 0.1 V; with 10 kOhm load |
for signal "1", min. | L+/L1 |
Output current |
for signal "1" rated value | 2 000 mA |
Total current of the outputs (per group) |
all mounting positions |
— Current per conductor/group, max. | 8 A |
Relay outputs |
Number of operating cycles, max. | 10 000 000; mechanically 10 million, at rated load voltage 100 000 |
Switching capacity of contacts |
— with inductive load, max. | 0.75 A; each output |
— on lamp load, max. | 200 W; 30 W with DC, 200 W with AC |
— with resistive load, max. | 0.75 A; each output |
Cable length |
shielded, max. | 500 m |
unshielded, max. | 150 m |
Encoder |
Connectable encoders |
2-wire sensor | Yes |
— permissible quiescent current (2-wire sensor), max. | 1 mA |
Potential separation |
Potential separation digital inputs |
Potential separation digital inputs | Yes; Optocoupler |
between the channels, in groups of | 4 |
Potential separation digital outputs |
Potential separation digital outputs | Yes; Relays |
between the channels, in groups of | 4 |
Isolation |
Isolation tested with | 500 V AC |
Connection method |
Plug-in I/O terminals | Yes |
Dimensions |
Width | 46 mm |
Height | 80 mm |
Depth | 62 mm |
Weights |
Weight, approx. | 160 g |
last modified: | 03/13/2019 |