6ES7134-7SD51-0AB0
ET200ISP, EL-MOD., 4 AI RTD, PT100/NI100

From SIEMENS

SIMATIC DP, electronics module for ET200iSP, 4 AI, RTD, for connection of resistance thermometers Pt100/NI100
Input current
Current consumption, typ.19 mA
from supply voltage L+, max.22 mA
Power loss
Power loss, typ.0.4 W
Analog inputs
Number of analog inputs4
Cycle time (all channels) max.320 ms; 66 ms basic conversion time x 4 channels with interference frequency suppression 60 Hz, 80 ms basic conversion time x 4 channels with interference frequency suppression 50 Hz
Technical unit for temperature measurement adjustableYes
Input ranges (rated values), resistance thermometer
Ni 100Yes
Input resistance (Ni 100)2 000 kΩ
Pt 100Yes
Input resistance (Pt 100)2 000 kΩ
Input ranges (rated values), resistors
0 to 600 ohmsYes; Also 1 000 ohms
Input resistance (0 to 600 ohms)1 000 kΩ
Characteristic linearization
parameterizableYes
— for resistance thermometerYes
Cable length
shielded, max.500 m
Analog value generation for the inputs
Measurement principleintegrating (Sigma-Delta)
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.16 bit
Integration time, parameterizableYes
Basic conversion time, including integration time (ms)80 ms at 50 Hz; 66 ms at 60 Hz
— additional conversion time for wire-break monitoring5 ms
Interference voltage suppression for interference frequency f1 in Hz50 / 60 Hz
Smoothing of measured values
parameterizableYes; in 4 stages
Step: NoneYes; 1x cycle time
Step: lowYes; 4x cycle time
Step: MediumYes; 32x cycle time
Step: HighYes; 64x cycle time
Encoder
Connection of signal encoders
for resistance measurement with two-wire connectionYes
for resistance measurement with three-wire connectionYes
for resistance measurement with four-wire connectionYes
Errors/accuracies
Linearity error (relative to input range), (+/-)0.015 %
Temperature error (relative to input range), (+/-)0.02 %/K
Crosstalk between the inputs, min.-50 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.01 %
Operational error limit in overall temperature range
Resistance thermometer, relative to input range, (+/-)0.15 %; Applies to resistances standard ±0.8 K, climatic ±0.3 K
Basic error limit (operational limit at 25 °C)
Resistance thermometer, relative to input range, (+/-)0.1 %; Applies to resistances standard ±0.5 K, climatic ±0.2 K
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
Series mode interference (peak value of interference < rated value of input range), min.70 dB
Common mode interference, min.90 dB
Interrupts/diagnostics/status information
Alarms
Diagnostic alarmYes
Limit value alarmYes
Diagnostic messages
Diagnostic information readableYes
Wire-breakYes
Short-circuitYes
Group errorYes
Diagnostics indication LED
Group error SF (red)Yes
Potential separation
Potential separation analog inputs
between the channelsNo
between the channels and backplane busYes
Between the channels and load voltage L+Yes; Channels and power bus
Standards, approvals, certificates
CE markYes
Highest safety class achievable in safety mode
Performance level according to ISO 13849-1none
SIL acc. to IEC 61508No
Use in hazardous areas
Type of protection acc. to EN 50020 (CENELEC)II2 G (1) GD Ex ib[ia] IIC T4 and I M2 Ex ib[ia] I
Type of protection acc. to KEMA04 ATEX 1247
Dimensions
Width30 mm
Height129 mm
Depth136.5 mm
Weights
Weight, approx.230 g
last modified:03/13/2019