6ES7134-0HF01-0XB0
ET200B, EL-MOD., 4AI, 0/4-20MA, +/-10V

From SIEMENS

*** SPARE PART*** SIMATIC DP, ELECTRONIC MODULE ANALOG, FOR ET 200B, W=160MM, 4AI 0(4)...20MA; +/- 10V, FAST CONVERSION, 12 BITS
General information
Usable terminal blockTB8
Supply voltage
Rated value (DC)24 V; Value at t < 0.5 s: 35 V
permissible range, lower limit (DC)18.5 V
permissible range, upper limit (DC)30.2 V
Input current
Current consumption, typ.70 mA; Logic
Power loss
Power loss, typ.1.8 W
Analog inputs
Number of analog inputs4
permissible input voltage for voltage input (destruction limit), max.30 V; ±30 V (static) or ±75 V (pulse for max. 1 ms and mark to space ratio 1:20)
permissible input current for current input (destruction limit), max.24 mA
Cycle time (all channels) max.5 ms
Input ranges
VoltageYes
CurrentYes
Input ranges (rated values), voltages
-1.25 V to +1.25 VYes
Input resistance (-1.25 V to +1.25 V)100 kΩ
-10 V to +10 VYes
Input resistance (-10 V to +10 V)100 kΩ
-2.5 V to +2.5 VYes
Input resistance (-2.5 V to +2.5 V)100 kΩ
-5 V to +5 VYes
Input resistance (-5 V to +5 V)100 kΩ
Input ranges (rated values), currents
0 to 20 mAYes
Input resistance (0 to 20 mA)125 Ω
-20 mA to +20 mAYes
Input resistance (-20 mA to +20 mA)125 Ω
4 mA to 20 mAYes
Input resistance (4 mA to 20 mA)125 Ω
Cable length
shielded, max.100 m
Analog value generation for the inputs
Measurement principlesuccessive approximation
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.12 bit; Two's complement
Integration time (ms)0.1 ms / channel
Encoder
Connection of signal encoders
for voltage measurementYes
for voltage measurement as 2-wire transducerYes
for current measurement as 2-wire transducerYes
for current measurement as 4-wire transducerYes
Errors/accuracies
Operational error limit in overall temperature range
Voltage, relative to input range, (+/-)32 %; 0 to 60°C
Current, relative to input range, (+/-)41 %; 0 to 60°C
Basic error limit (operational limit at 25 °C)
Voltage, relative to input range, (+/-)0.15 %
Current, relative to input range, (+/-)0.2 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
Common mode interference, min.70 dB; Upp < 1 V
Interfaces
PROFIBUS DP
Transmission rate, max.12 Mbit/s
Protocols
Bus protocol/transmission protocolPROFIBUS DP
Interrupts/diagnostics/status information
Alarms
Diagnostic alarmYes; Parameterizable
Limit value alarmYes; Parameterizable, channels 0 and 2
Diagnostic messages
OverrangeYes; Rated range
Wire-break in signal transmitter cableYes; Measuring range 4 to 20 mA only
Diagnostics indication LED
RUN LEDYes
Bus fault BF (red)Yes
Potential separation
between electronic block and PROFIBUS DPYes
Potential separation analog inputs
Potential separation analog inputsNo
Permissible potential difference
between the inputs (UCM)max. ±10 V
Between the inputs and MANA (UCM)max. ±1 V
Degree and class of protection
Degree of protection acc. to EN 60529IP20
Ambient conditions
Ambient temperature during operation
horizontal installation, min.0 °C
horizontal installation, max.60 °C; 41 °C for other mountings
Air pressure acc. to IEC 60068-2-13
permissible range, lower limit795 hPa
permissible range, upper limit1 080 hPa
Relative humidity
Operation, min.15 %
Operation, max.95 %; RH class 2 in accordance with IEC 1131-2
Vibrations
Operation, tested according to IEC 60068-2-6Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g)
Shock testing
tested according to IEC 60068-2-27Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms
Connection method
Design of electrical connection for the inputs and outputsScrew-type and spring-loaded terminals, permanent wiring; 3 and 4-wire connection
Dimensions
Width160 mm; EB and TB
Height130 mm; EB and TB
Depth60 mm; EB and TB
Weights
Weight, approx.550 g; EB and TB
last modified:03/13/2019