| SIPLUS HCS724I LA724I power output for central connection ZA724I, Note: The associated 3 units mating connectors for connection of the radiation source are not included in the scope of delivery of the power output and can be optionally ordered under the order number WKF: 40018384 . For ordering information, see respective entry of the connector in PMD |
General information |
Product type designation | LA724I |
Installation type/mounting |
Mounting type | Screws in fixing lugs at top and bottom |
Mounting position | vertical |
Type of ventilation | Self ventilation or forced ventilation |
Supply voltage |
Type of supply voltage | AC |
Rated value (AC) | 230 V |
Relative negative tolerance | 18 % |
Relative positive tolerance | 15 % |
Line frequency |
Rated value 50 Hz | Yes |
Rated value 60 Hz | Yes |
Relative symmetrical tolerance | 5 % |
Connection method |
Design of electrical connection for supply voltage | Bus bar or ring cable lug |
Input voltage |
Design of the power supply | Power supply via central connection |
Power electronics |
Type of load | Ohmic load |
Type of control of the heating elements | Half-wave control |
Power capacity, max. | 22 kW |
For phase against neutral with fan at 40 °C, max. | 22 kW |
For phase against neutral without fan at 40 °C, max. | 14.4 kW |
Switching capacity current per busbar, max. | 120 A |
Switching capacity current per phase, max. | 32 A |
Heating power |
Number of digital outputs | 24 |
Number of heating elements per output, max. | 5 |
Output voltage for star connection | 230 V |
Power carrying capacity per output, min. | 75 W |
Power carrying capacity per output, max. | 1 150 W |
Output current for heating power | 5 A |
Design of short-circuit protection per output | Fuse 5 A |
Design of overvoltage protection | Transil diodes |
Connection method |
Design of electrical connection at output for heating and fan | Socket strip, 8-pole |
— Connectable conductor cross-sections, solid | 1x (0.2 ... 1.5 mm²) |
— Connectable conductor cross-sections, finely stranded with wire end processing | 1x (0.2 ... 1.5 mm²) |
— Connectable conductor cross-sections for AWG cables, stranded | 28 ... 16 |
Interfaces |
Interfaces/bus type | system interface |
Interrupts/diagnostics/status information |
Number of status displays | 4 |
LED status display | 1 LED green = LA status indicator, 3 LEDs red = fault indicator LA per phase |
Diagnostics function | Voltage and current diagnosis |
Diagnostic messages |
Wire-break | Yes |
Fuse blown | Yes |
Load failure | Yes |
Integrated Functions |
Monitoring functions |
Temperature monitoring | Yes |
Type of temperature monitoring | NTC thermistor |
Measuring functions |
Current measurement | Yes |
Measuring inputs for current |
— Design of electrical connection at the measuring inputs for current | Internal |
Potential separation |
between the outputs | No |
Isolation |
Overvoltage category | III |
Degree of pollution | 2 |
EMC |
EMC interference emission | Limit value class A to EN 55011 group 1 |
Electrostatic discharge acc. to IEC 61000-4-2 | 4 kV contact discharge / 8 kV air discharge |
Field-related interference acc. to IEC 61000-4-3 | 10 V/m (80 ... 1 000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0 ... 2.7 GHz) |
Conducted interference due to burst acc. to IEC 61000-4-4 | 2 kV voltage supply cables / 2 kV signal cables |
Conducted interference due to surge acc. to IEC 61000-4-5 | on power supply and signal cables: 1 kV symmetrical, 2 kV unsymmetrical |
Conducted interference due to high-frequency radiation acc. to IEC 61000-4-6 | 10 V (0.15 ... 80 MHz) |
Degree and class of protection |
IP degree of protection | IP20 |
Standards, approvals, certificates |
Certificate of suitability | CE, KCC |
CE mark | Yes |
KC approval | Yes |
EAC (formerly Gost-R) | Yes |
China RoHS compliance | Yes |
Reference designation according to DIN EN 81346-2 | Q |
Ambient conditions |
Ambient temperature during operation |
min. | 0 °C |
max. | 55 °C |
Ambient temperature during storage/transportation |
Storage, min. | -40 °C |
Storage, max. | 70 °C |
Transportation, min. | -40 °C |
Transportation, max. | 70 °C |
Air pressure acc. to IEC 60068-2-13 |
Operation, min. | 860 hPa |
Operation, max. | 1 080 hPa |
Storage, min. | 660 hPa |
Storage, max. | 1 080 hPa |
Altitude during operation relating to sea level |
Installation altitude above sea level, max. | 2 000 m |
Relative humidity |
Operation at 25 ℃, max. | 95 % |
Vibrations |
Vibration resistance during operation acc. to IEC 60068-2-6 | 10 ... 58 Hz / 0.15 mm, 58 ... 150 Hz / 1 g |
Vibration resistance during storage acc. to IEC 60068-2-6 | 5 ... 9 Hz / 3.5 mm, 9 ... 500 Hz / 1 g |
Shock testing |
Shock resistance during operation acc. to IEC 60068-2-27 | 15 g / 11 ms / 3 shocks/axis |
Shock resistance during storage acc. to IEC 60068-2-29 | 25 g / 6 ms / 1 000 shocks/axis |
Dimensions |
Width | 50 mm |
Height | 480 mm |
Depth | 210 mm |
last modified: | 03/25/2019 |