6BK1700-2BA00-0AA0
HCS Power output module LA724I

From SIEMENS

SIPLUS HCS724I LA724I power output for central connection ZA724I, Note: The associated 3 units mating connectors for connection of the radiation source are not included in the scope of delivery of the power output and can be optionally ordered under the order number WKF: 40018384 . For ordering information, see respective entry of the connector in PMD
General information
Product type designationLA724I
Installation type/mounting
Mounting typeScrews in fixing lugs at top and bottom
Mounting positionvertical
Type of ventilationSelf ventilation or forced ventilation
Supply voltage
Type of supply voltageAC
Rated value (AC)230 V
Relative negative tolerance18 %
Relative positive tolerance15 %
Line frequency
Rated value 50 HzYes
Rated value 60 HzYes
Relative symmetrical tolerance5 %
Connection method
Design of electrical connection for supply voltageBus bar or ring cable lug
Input voltage
Design of the power supplyPower supply via central connection
Power electronics
Type of loadOhmic load
Type of control of the heating elementsHalf-wave control
Power capacity, max.22 kW
For phase against neutral with fan at 40 °C, max.22 kW
For phase against neutral without fan at 40 °C, max.14.4 kW
Switching capacity current per busbar, max.120 A
Switching capacity current per phase, max.32 A
Heating power
Number of digital outputs24
Number of heating elements per output, max.5
Output voltage for star connection230 V
Power carrying capacity per output, min.75 W
Power carrying capacity per output, max.1 150 W
Output current for heating power5 A
Design of short-circuit protection per outputFuse 5 A
Design of overvoltage protectionTransil diodes
Connection method
Design of electrical connection at output for heating and fanSocket strip, 8-pole
— Connectable conductor cross-sections, solid1x (0.2 ... 1.5 mm²)
— Connectable conductor cross-sections, finely stranded with wire end processing1x (0.2 ... 1.5 mm²)
— Connectable conductor cross-sections for AWG cables, stranded28 ... 16
Interfaces
Interfaces/bus typesystem interface
Interrupts/diagnostics/status information
Number of status displays4
LED status display1 LED green = LA status indicator, 3 LEDs red = fault indicator LA per phase
Diagnostics functionVoltage and current diagnosis
Diagnostic messages
Wire-breakYes
Fuse blownYes
Load failureYes
Integrated Functions
Monitoring functions
Temperature monitoringYes
Type of temperature monitoringNTC thermistor
Measuring functions
Current measurementYes
Measuring inputs for current
— Design of electrical connection at the measuring inputs for currentInternal
Potential separation
between the outputsNo
Isolation
Overvoltage categoryIII
Degree of pollution2
EMC
EMC interference emissionLimit value class A to EN 55011 group 1
Electrostatic discharge acc. to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
Field-related interference acc. to IEC 61000-4-310 V/m (80 ... 1 000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0 ... 2.7 GHz)
Conducted interference due to burst acc. to IEC 61000-4-42 kV voltage supply cables / 2 kV signal cables
Conducted interference due to surge acc. to IEC 61000-4-5on power supply and signal cables: 1 kV symmetrical, 2 kV unsymmetrical
Conducted interference due to high-frequency radiation acc. to IEC 61000-4-610 V (0.15 ... 80 MHz)
Degree and class of protection
IP degree of protectionIP20
Standards, approvals, certificates
Certificate of suitabilityCE, KCC
CE markYes
KC approvalYes
EAC (formerly Gost-R)Yes
China RoHS complianceYes
Reference designation according to DIN EN 81346-2Q
Ambient conditions
Ambient temperature during operation
min.0 °C
max.55 °C
Ambient temperature during storage/transportation
Storage, min.-40 °C
Storage, max.70 °C
Transportation, min.-40 °C
Transportation, max.70 °C
Air pressure acc. to IEC 60068-2-13
Operation, min.860 hPa
Operation, max.1 080 hPa
Storage, min.660 hPa
Storage, max.1 080 hPa
Altitude during operation relating to sea level
Installation altitude above sea level, max.2 000 m
Relative humidity
Operation at 25 ℃, max.95 %
Vibrations
Vibration resistance during operation acc. to IEC 60068-2-610 ... 58 Hz / 0.15 mm, 58 ... 150 Hz / 1 g
Vibration resistance during storage acc. to IEC 60068-2-65 ... 9 Hz / 3.5 mm, 9 ... 500 Hz / 1 g
Shock testing
Shock resistance during operation acc. to IEC 60068-2-2715 g / 11 ms / 3 shocks/axis
Shock resistance during storage acc. to IEC 60068-2-2925 g / 6 ms / 1 000 shocks/axis
Dimensions
Width50 mm
Height480 mm
Depth210 mm