6AG1123-2GB03-2AX0
SIPLUS HMI KTP700 BASIC

From SIEMENS

SIPLUS HMI KTP700 Basic Color PN -20...+50°C with conformal coating based on "6AV2123-2GB03-0AX0 . ""7"""" TFT" "display, 65536 colors"" PROFINET" interface
General information
Product type designationKTP700 Basic color PN
Display
Design of displayTFT widescreen display, LED backlighting
Screen diagonal7 in
Display width154.1 mm
Display height85.9 mm
Number of colors65 536
Resolution (pixels)
Horizontal image resolution800 Pixel
Vertical image resolution480 Pixel
Backlighting
MTBF backlighting (at 25 °C)20 000 h
Backlight dimmableYes
Control elements
Keyboard fonts
Function keys
— Number of function keys8
Keys with LEDNo
System keysNo
Numeric keyboardYes; Onscreen keyboard
alphanumeric keyboardYes; Onscreen keyboard
Touch operation
Design as touch screenYes
Installation type/mounting
Mounting in portrait format possibleYes
Mounting in landscape format possibleYes
maximum permissible angle of inclination without external ventilation35°
Supply voltage
Type of supply voltageDC
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Input current
Current consumption (rated value)230 mA
Starting current inrush I²t0.2 A²·s
Power
Active power input, typ.5.5 W
Processor
Processor typeARM
Memory
FlashYes
RAMYes
Memory available for user data10 Mbyte
Type of output
Acoustics
BuzzerYes
SpeakerNo
Time of day
Clock
Hardware clock (real-time)Yes
Software clockYes
retentiveYes
synchronizableYes
Interfaces
Number of industrial Ethernet interfaces1
Number of RS 485 interfaces0
Number of RS 422 interfaces0
Number of RS 232 interfaces0
Number of USB interfaces1; Up to 16 GB
Number of 20 mA interfaces (TTY)0
Number of parallel interfaces0
Number of other interfaces0
Number of SD card slots0
With software interfacesNo
Industrial Ethernet
Industrial Ethernet status LED2
Protocols
PROFINETYes
Supports protocol for PROFINET IONo
IRTNo
PROFIBUSNo
MPINo
Protocols (Ethernet)
TCP/IPYes
DHCPYes
SNMPYes
DCPYes
LLDPYes
WEB characteristics
HTTPNo
HTMLNo
Further protocols
CANNo
EtherNet/IPYes
MODBUSYes; Modicon (MODBUS TCP/IP)
Interrupts/diagnostics/status information
Diagnostic messages
Diagnostic information readableNo
EMC
Emission of radio interference acc. to EN 55 011
Limit class A, for use in industrial areasYes
Limit class B, for use in residential areasNo
Degree and class of protection
IP (at the front)IP65
Enclosure Type 4 at the frontYes
Enclosure Type 4x at the frontYes
IP (rear)IP20
Ambient conditions
Suited for indoor useYes
Suited for outdoor useNo
Ambient temperature during operation
Operation (vertical installation)
— For vertical installation, min.-20 °C
— For vertical installation, max.50 °C
Operation (max. tilt angle)
— At maximum tilt angle, min.-20 °C
— At maximum tilt angle, min.40 °C
Operation (vertical installation, portrait format)
— For vertical installation, min.-20 °C
— For vertical installation, max.40 °C
Operation (max. tilt angle, portrait format)
— At maximum tilt angle, min.-20 °C
— At maximum tilt angle, min.35 °C
Ambient temperature during storage/transportation
min.-20 °C
max.60 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Resistance
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Remark
— Note regarding classification of environmental conditions acc. to EN 60721* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high availability
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Operating systems
proprietaryYes
pre-installed operating system
Windows CENo
Configuration
Message indicatorYes
Alarm system (incl. buffer and acknowledgment)Yes
Process value display (output)Yes
Process value default (input) possibleYes
Recipe managementYes
Configuration software
STEP 7 Basic (TIA Portal)Yes; via integrated WinCC Basic (TIA Portal)
STEP 7 Professional (TIA Portal)Yes; via integrated WinCC Basic (TIA Portal)
WinCC flexible CompactNo
WinCC flexible StandardNo
WinCC flexible AdvancedNo
WinCC Basic (TIA Portal)Yes
WinCC Comfort (TIA Portal)Yes
WinCC Advanced (TIA Portal)Yes
WinCC Professional (TIA Portal)Yes
Languages
Online languages
Number of online/runtime languages10
Project languages
Languages per project32
Functionality under WinCC (TIA Portal)
LibrariesYes
Number of Visual Basic ScriptsNo
Task plannerYes
time-controlledNo
task-controlledYes
Help systemYes
Number of characters per info text500
Message system
Number of alarm classes32
Bit messages
— Number of bit messages1 000
Analog messages
— Number of analog messages25
S7 alarm number procedureNo
System messages HMIYes
System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.)Yes; System message buffer of the SIMATIC S7-1200 and S7-1500
Number of characters per message80
Number of process values per message8
Acknowledgment groupsYes
Message indicatorYes
Message bufferYes
— Number of entries256
— Circulating bufferYes
— retentiveYes
— maintenance-freeYes
Recipe management
Number of recipes50
Data records per recipe100
Entries per data record100
Size of internal recipe memory256 kbyte
Recipe memory expandableNo
Variables
Number of variables per device800
Number of variables per screen100
Limit valuesYes
MultiplexingYes
StructuresNo
ArraysYes
Images
Number of configurable images250
Permanent window/defaultYes
Global imageYes
Image selection by PLCYes
Image number in the PLCYes
Image objects
Number of objects per image100
Text fieldsYes
I/O fieldsYes
Graphic I/O fields (graphics list)Yes
Symbolic I/O fields (text list)Yes
Date/time fieldsYes
SwitchesYes
ButtonsYes
Graphic displayYes
IconsYes
Geometric objectsYes
Complex image objects
Number of complex objects per screen10
Alarm viewYes
Trend viewYes
User viewYes
Status/controlNo
Sm@rtClient viewNo
Recipe viewYes
f(x) trend viewNo
System diagnostics viewYes; System message buffer of the SIMATIC S7-1200 and S7-1500
Media PlayerNo
Bar graphsYes
SlidersNo
Pointer instrumentsNo
Analog/digital clockNo
Lists
Number of text lists per project150
Number of entries per text list100
Number of graphics lists per project100
Number of entries per graphics list100
Archiving
Number of archives per device2
Number of entries per archive10 000
Message archiveYes
Process value archiveYes
Archiving methods
— Sequential archiveYes
— Short-term archiveYes
Memory location
— Memory cardNo
— USB memoryYes
— EthernetNo
Data storage format
— CSVNo
— TXTYes
— RDBNo
Security
Number of user groups50
Number of user rights32
Number of users50
Password export/importYes; Possible via ProSave
SIMATIC LogonNo
Character sets
Keyboard fonts
— US EnglishYes
Transfer (upload/download)
MPI/PROFIBUS DPNo
USBNo
EthernetYes
using external storage mediumNo
Process coupling
S7-1200Yes
S7-1500Yes
S7-200Yes
S7-300/400Yes
LOGO!Yes
WinACYes
SINUMERIKNo
SIMOTIONYes
Allen Bradley (EtherNet/IP)Yes
Allen Bradley (DF1)No
Mitsubishi (MC TCP/IP)Yes
Mitsubishi (FX)No
OMRON (FINS TCP)No
OMRON (LINK/Multilink)No
Modicon (Modbus TCP/IP)Yes
Modicon (Modbus)No
Service tools/configuration aids
Backup/Restore manuallyYes; Possible via ProSave
Backup/Restore automaticallyNo
SimulationYes
Device switchoverYes
Peripherals/Options
Peripherals
PrinterNo
SIMATIC HMI MM memory card: Multi Media CardNo
SIMATIC HMI SD memory card: Secure Digital memory cardNo
USB memoryYes
Mechanics/material
Enclosure material (front)
PlasticYes
AluminumNo
Stainless steelNo
Dimensions
Width of the housing front214 mm
Height of housing front158 mm
Mounting cutout, width197 mm
Mounting cutout, height141 mm
Overall depth39 mm
Weights
Weight without packaging780 g
Weight incl. packaging990 g
last modified:03/13/2019