| Enclosure for command devices, 22 mm, round, Enclosure material metal, Enclosure top part yellow, with protective collar, 1 control point metal, A=EMERGENCY STOP mushroom pushbutton red, 40 mm, rotate-to-unlatch, 1 NC, screw terminal, floor mounting, 1xM20 each on top and bottom |
Product brand name | SIRIUS ACT |
Product designation | Enclosures |
Product type designation | 3SU1 |
Manufacturer's article number | |
of supplied contact module | A1 = 3SU1400-2AA10-1CA0 |
of supplied contact module at the command point A 1 | |
of the supplied holder | A = 3SU1550-0AA10-0AA0 |
of the supplied holder at the command point A | |
of the supplied actuator | A = 3SU1050-1HB20-0AA0 |
of the supplied actuator at the command point A | |
of supplied empty enclosure | |
Enclosure |
Design of the housing | with protective collar |
Shape of the enclosure front | Square |
Material of the enclosure | metal |
Number of command points | 1 |
Product component | |
EMERGENCY STOP device | Yes |
protective collar | No |
Color | |
of top part of the enclosure | yellow |
Delivery state | |
as a kit | No |
pre-wired on strip terminal | No |
Mounting type of the enclosure | Vertical |
Actuator |
Design of the operating mechanism | Emergency stop mushroom pushbutton |
Suitability for use EMERGENCY OFF switch | Yes |
Product feature | |
lockout | No |
Product extension optional Light source | No |
Color | |
of the actuating element | Red |
Material of the actuating element | plastic |
Shape of the actuating element | round |
Number of contact modules | 1 |
Type of unlocking device | A = rotate-to-unlatch mechanism |
Front ring |
Product component front ring | No |
Design of the front ring | Standard |
Holder |
Material of the holder | Metal |
Display |
Number of LED modules | 0 |
General technical data |
Product function | |
positive opening | Yes |
EMERGENCY OFF function | Yes |
EMERGENCY STOP function | Yes |
Protection class IP | IP66, IP67, IP69(IP69K) |
Degree of protection NEMA rating | NEMA 1, 2, 3, 3R, 4, 4X, 12, 13 |
Shock resistance | |
acc. to IEC 60068-2-27 | Sinusoidal half-wave 50 g / 11 ms |
Reference code acc. to DIN EN 81346-2 | S |
Reference code acc. to DIN EN 61346-2 | S |
Continuous current of the C characteristic MCB | 10 A; for a short-circuit current smaller than 400 A |
Continuous current of the quick DIAZED fuse link | 10 A |
Continuous current of the DIAZED fuse link gG | 10 A |
Operating voltage | |
at AC | |
— at 50 Hz rated value | 5 ... 500 V |
— at 60 Hz rated value | 5 ... 500 V |
at DC | |
— rated value | 5 ... 500 V |
Auxiliary circuit |
Design of the contact of auxiliary contacts | Silver alloy |
Number of NC contacts for auxiliary contacts | 1 |
Number of NO contacts for auxiliary contacts | 0 |
Number of CO contacts | |
for auxiliary contacts | 0 |
Connections/Terminals |
Type of electrical connection | |
of modules and accessories | Screw-type terminal |
Type of electrical connection on enclosure | Cable routing above and below, both 1 x M20 |
Tightening torque of the screws in the bracket | 1 ... 1.2 N·m |
Tightening torque of mounting screws in the enclosure cover | 1.5 ... 1.7 N·m |
Tightening torque | |
with screw-type terminals | 0.8 ... 0.9 N·m |
Interfaces |
Design of the interface | |
for communication | without |
Ambient conditions |
Ambient temperature | |
during operation | -25 ... +70 °C |
during storage | -40 ... +80 °C |
Environmental category during operation acc. to IEC 60721 | 3M6, 3S2, 3B2, 3C3, 3K6 (with relative air humidity of 10 ... 95 %, no condensation in operation permitted for all devices behind front panel) |
Installation/ mounting/ dimensions |
Mounting type | |
of modules and accessories | Floor mounting |
Height | 89.4 mm |
Width | 85 mm |
Depth | 112.5 mm |
Shape of the installation opening | round |
Accessories |
Number of labels | 0 |
Marking of the name plate for command devices | A = I |