| Power contactor, AC-3 12 A, 5.5 kW / 400 V 1 NO, 24 V DC 3-pole, Size S00 Screw terminal Multi-unit packaging Pack = 42 units !!! Phased-out product !!! Successor is SIRIUS 3RT2 |
Product brand name | SIRIUS |
Product designation | power contactor |
General technical data |
Size of contactor | S00 |
Degree of pollution | 3 |
Protection class IP | |
on the front | IP20 |
of the terminal | IP20 |
Mechanical service life (switching cycles) | |
of contactor typical | 30 000 000 |
of the contactor with added electronics-compatible auxiliary switch block typical | 5 000 000 |
of the contactor with added auxiliary switch block typical | 10 000 000 |
Reference code acc. to DIN EN 81346-2 | Q |
Ambient conditions |
Installation altitude at height above sea level | |
maximum | 2 000 m |
Main circuit |
Number of poles for main current circuit | 3 |
Number of NO contacts for main contacts | 3 |
Number of NC contacts for main contacts | 0 |
Operating current | |
at AC-1 at 400 V | |
— at ambient temperature 40 °C rated value | 22 A |
at AC-1 | |
— up to 690 V at ambient temperature 40 °C rated value | 22 A |
— up to 690 V at ambient temperature 60 °C rated value | 20 A |
at AC-3 | |
— at 400 V rated value | 12 A |
at AC-4 at 400 V rated value | 8.5 A |
Operating current | |
at 1 current path at DC-1 | |
— at 24 V rated value | 20 A |
— at 110 V rated value | 2.1 A |
with 2 current paths in series at DC-1 | |
— at 24 V rated value | 20 A |
— at 110 V rated value | 12 A |
with 3 current paths in series at DC-1 | |
— at 24 V rated value | 20 A |
— at 110 V rated value | 20 A |
Operating current | |
at 1 current path at DC-3 at DC-5 | |
— at 24 V rated value | 20 A |
— at 110 V rated value | 0.15 A |
with 2 current paths in series at DC-3 at DC-5 | |
— at 24 V rated value | 20 A |
— at 110 V rated value | 0.35 A |
with 3 current paths in series at DC-3 at DC-5 | |
— at 24 V rated value | 20 A |
— at 110 V rated value | 20 A |
Operating power | |
at AC-1 | |
— at 400 V rated value | 13 kW |
at AC-2 at 400 V rated value | 5.5 kW |
at AC-3 | |
— at 400 V rated value | 5.5 kW |
— at 500 V rated value | 5.5 kW |
— at 690 V rated value | 5.5 kW |
Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor | 1.24 W |
Control circuit/ Control |
Type of voltage of the control supply voltage | DC |
Control supply voltage at DC | |
rated value | 24 V |
Operating range factor control supply voltage rated value of magnet coil at DC | |
initial value | 0.85 |
Full-scale value | 1.1 |
Closing power of magnet coil at DC | 3.3 W |
Holding power of magnet coil at DC | 3.3 W |
Auxiliary circuit |
Number of NC contacts for auxiliary contacts | |
instantaneous contact | 0 |
Number of NO contacts for auxiliary contacts | |
instantaneous contact | 1 |
Operating current at AC-12 maximum | 10 A |
Operating current at AC-15 | |
at 230 V rated value | 6 A |
at 400 V rated value | 3 A |
Operating current at DC-12 | |
at 60 V rated value | 6 A |
at 110 V rated value | 3 A |
at 220 V rated value | 1 A |
Operating current at DC-13 | |
at 24 V rated value | 10 A |
at 60 V rated value | 2 A |
at 110 V rated value | 1 A |
at 220 V rated value | 0.3 A |
Contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
Short-circuit protection |
Design of the fuse link | |
for short-circuit protection of the main circuit | |
— with type of coordination 1 required | fuse gL/gG: 35 A |
— with type of assignment 2 required | fuse gL/gG: 20 A |
for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A |
Installation/ mounting/ dimensions |
| |
(mounting type) | screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 |
Mounting type Side-by-side mounting | Yes |
Height | 57.5 mm |
Width | 45 mm |
Depth | 72 mm |
Required spacing | |
for grounded parts | |
— at the side | 6 mm |
Connections/Terminals |
Type of electrical connection | |
for main current circuit | screw-type terminals |
for auxiliary and control current circuit | screw-type terminals |
Type of connectable conductor cross-sections | |
for main contacts | |
— solid | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²) |
— single or multi-stranded | 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²) |
— finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
at AWG conductors for main contacts | 2x (20 ... 16), 2x (18 ... 14), 1x 12 |
Type of connectable conductor cross-sections | |
for auxiliary contacts | |
— solid | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²) |
— finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
at AWG conductors for auxiliary contacts | 2x (20 ... 16), 2x (18 ... 14), 1x 12 |