| Separation amplifier 24 V AC/DC, 3-way separation input: 4-20 mA output: 4-20 mA Spring-type terminal (push-in) |
Product brand name | SIRIUS |
Product category | Signal converter |
Product designation | Single-range converters |
Design of the product | active |
Product type designation | 3RS70 |
General technical data |
Display version LED | Yes |
Number of channels | 1 |
Consumed active power | 0.29 W |
Insulation voltage | |
for overvoltage category III according to IEC 60664 | |
— with degree of pollution 3 rated value | 50 V |
Surge voltage resistance rated value | 2 500 V |
Protection class IP | IP20 |
Shock resistance | |
acc. to IEC 60068-2-27 | sinusoidal half-wave 15g / 11 ms |
Reference code acc. to DIN EN 81346-2 | T |
Reference code acc. to DIN EN 61346-2 | K |
Supply voltage |
Supply voltage at AC | |
at 50 Hz rated value | 24 V |
at 60 Hz rated value | 24 V |
Supply voltage at DC rated value | 24 V |
Supply voltage frequency | |
rated value | 60 ... 50 Hz |
Operating range factor supply voltage rated value | |
at AC at 50 Hz | 0.8 ... 1.1 |
at AC at 60 Hz | 0.8 ... 1.1 |
at DC | 0.8 ... 1.1 |
Precision |
Relative metering precision | 0.1 % |
Relative linearity deviation | 0.05 % |
Temperature drift per °C | 0.015 %/°C |
Voltage ripple maximum | 20 mV |
Limit frequency | 30 Hz |
Settling time for 1 % deviation | 17 ms |
Rise time | 6 ms |
Main circuit |
Type of voltage | AC/DC |
Inputs/ Outputs |
Input voltage | 30 V |
Property of the output Short-circuit proof | Yes |
Type of signal at input | 4 ... 20 mA |
Type of signal at output | 4 ... 20 mA |
Input impedance of current input maximum | 100 Ω |
Outputs |
Load | |
at the current output maximum | 500 Ω |
Electromagnetic compatibility |
EMC emitted interference | |
acc. to IEC 60947-1 | Environment B |
EMI immunity | |
acc. to IEC 60947-1 | corresponds to degree of severity 3 |
Conducted interference | |
due to burst acc. to IEC 61000-4-4 | 1 kV 5/50 ns |
due to conductor-conductor surge acc. to IEC 61000-4-5 | 1 kV |
Field-bound parasitic coupling acc. to IEC 61000-4-3 | 10 V/m |
Electrostatic discharge acc. to IEC 61000-4-2 | 6 kV contact discharge / 8 kV air discharge |
Galvanic isolation |
Design of the electrical isolation | 3 paths |
Galvanic isolation | |
between entrance and outlet | Yes |
between the outputs | No |
between the inputs | No |
between the voltage supply and other circuits | Yes |
Connections/Terminals |
Type of electrical connection | spring-loaded terminals |
Type of connectable conductor cross-sections | |
solid | 1x (0.25 ... 2.5 mm²) |
finely stranded with core end processing | 1x (0.25 ... 1.5 mm²) |
finely stranded without core end processing | 1x (0.25 ... 2.5 mm²) |
at AWG conductors solid | 1 x (20 ... 14) |
at AWG conductors stranded | 1x (20 ... 14) |
Connectable conductor cross-section | |
solid | 0.25 ... 2.5 mm² |
finely stranded with core end processing | 0.25 ... 1.5 mm² |
finely stranded without core end processing | 0.25 ... 2.5 mm² |
AWG number as coded connectable conductor cross section | |
solid | 20 ... 14 |
stranded | 20 ... 14 |
Installation/ mounting/ dimensions |
Mounting position | any |
Mounting type | snap-on mounting |
Height | 93 mm |
Width | 6.2 mm |
Depth | 72.5 mm |
Required spacing | |
with side-by-side mounting | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 0 mm |
— downwards | 0 mm |
— at the side | 0 mm |
for grounded parts | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 0 mm |
— at the side | 0 mm |
— downwards | 0 mm |
for live parts | |
— forwards | 0 mm |
— Backwards | 0 mm |
— upwards | 0 mm |
— downwards | 0 mm |
— at the side | 0 mm |
Ambient conditions |
Installation altitude at height above sea level | |
maximum | 2 000 m |
Ambient temperature | |
during operation | -25 ... +60 °C |
during storage | -40 ... +80 °C |
during transport | -40 ... +80 °C |
Relative humidity | |
during operation | 10 ... 95 % |