| SIRIUS motor starter M200D AS-i Communication: AS-Interface DOL starter Standard Mechanical switching AC-3, 5.5 kW / 400 V 1.5 A...12.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC without brake contact 4 DI / 1 DO AS-i Han Q4/2 - Han Q8/0 |
Product brand name | SIRIUS |
Product designation | Motor starters |
Design of the product | direct starter |
Product type designation | M200D |
Product function | |
on-site operation | No |
Control circuit interface to parallel wiring | No |
Power loss [W] typical | 30 W |
Insulation voltage rated value | 500 V |
Degree of pollution | 3 |
Surge voltage resistance rated value | 6 000 V |
maximum permissible voltage for safe isolation | |
between main and auxiliary circuit | 400 V |
between control and auxiliary circuit | 24 V |
Protection class IP | IP65 |
Shock resistance | 12g / 11 ms |
Mechanical service life (switching cycles) of the main contacts typical | 10 000 000 |
Type of assignment | 1 |
Certificate of suitability | CE |
Reference code acc. to DIN EN 61346-2 | Q |
Product function | |
direct start | Yes |
reverse starting | No |
Product component Motor brake output | No |
Product feature | |
brake control with 230 V AC | No |
brake control with 400 V AC | No |
brake control with 24 V DC | No |
brake control with 180 V DC | No |
brake control with 500 V DC | No |
Product extension braking module for brake control | No |
Product function Short circuit protection | Yes |
Design of short-circuit protection | circuit-breakers |
Trip class | CLASS 5, 10, 15, 20 |
Maximum short-circuit current breaking capacity (Icu) | |
at 400 V rated value | 50 000 A |
at 500 V rated value | 50 000 A |
EMC emitted interference acc. to IEC 60947-1 | CISPR11, ambience A (industrial sector) |
EMI immunity acc. to IEC 60947-1 | corresponds to degree of severity 3, ambience A (industrial sector) |
Conducted interference | |
due to burst acc. to IEC 61000-4-4 | 2 kV network connection / 1 kV control connection |
due to conductor-earth surge acc. to IEC 61000-4-5 | 2 kV |
due to conductor-conductor surge acc. to IEC 61000-4-5 | 1 kV |
Protection against electrical shock | finger-safe |
Main circuit |
Number of poles for main current circuit | 3 |
Design of the switching contact | electromechanical |
Adjustable pick-up value current of the current-dependent overload release | 1.5 ... 12 A |
Type of the motor protection | full motor protection |
Operating voltage rated value | 360 ... 440 V |
Operating current | |
at AC at 400 V rated value | 12 A |
at AC-3 at 400 V rated value | 12 A |
Operating power at AC-3 | |
at 400 V rated value | 5.5 kW |
at 500 V rated value | 5 500 W |
Product function | |
digital inputs parameterizable | Yes |
digital outputs parameterizable | Yes |
Number of digital inputs | 4 |
Number of sockets | |
for digital output signals | 1 |
for digital input signals | 4 |
Number of digital outputs | 1 |
Supply voltage |
Type of voltage of the supply voltage | DC |
Supply voltage 1 at DC rated value | 30 V |
minimum permissible | 26.5 V |
maximum permissible | 31.6 V |
Control circuit/ Control |
Type of voltage of the control supply voltage | DC |
Control supply voltage at DC | |
rated value | 20.4 ... 28.8 V |
Control supply voltage 1 | |
at DC rated value | 24 V |
at DC rated value | 20.4 ... 28.8 V |
at DC | 20.4 ... 28.8 V |
Power loss [W] in auxiliary and control circuit | |
in switching state OFF with bypass circuit | 2.0736 W |
in switching state ON with bypass circuit | 4.1184 W |
Response times |
Switch-on delay time | 85 ms |
Off-delay time | 65 ms |
Mounting position | vertical, horizontal, flat |
recommended | horizontal |
Mounting type | screw fixing |
Height | 215 mm |
Width | 294 mm |
Depth | 159 mm |
Installation altitude at height above sea level maximum | 2 000 m |
Ambient temperature | |
during operation | -25 ... +55 °C |
during storage | -40 ... +70 °C |
during transport | -40 ... +70 °C |
Relative humidity during operation | 10 ... 95 % |
Protocol is supported | |
PROFIBUS DP protocol | No |
PROFINET protocol | No |
Design of the interface | |
AS-interface protocol | Yes |
PROFINET protocol | No |
PROFIBUS DP protocol | No |
Product function Bus communication | Yes |
Protocol is supported AS-interface protocol | Yes |
Product function Control circuit interface with IO link | No |
Type of electrical connection of the communication interface | M12 plug |
Type of electrical connection | |
for main current circuit | plug according to ISO 23570, HAN Q4/2 |
for auxiliary and control current circuit | connector |
Type of electrical connection | |
1 for digital input signals | M12 socket |
1 for digital output signals | M12 socket |
2 for digital input signals | M12 socket |
3 for digital input signals | M12 socket |
4 for digital input signals | M12 socket |
Type of electrical connection | |
at the manufacturer-specific device interface | optical interface |
for device addressing | M12 plug |
for supply voltage line-side | M12 plug |