| SIRIUS Compact load feeder Reversing starter 690 V 42...70 V AC/DC 50...60 Hz 0.1...0.4 A IP20 Connection main circuit: plug-in, without terminals Connection control circuit: plug-in, without terminals |
Product brand name | SIRIUS |
Product designation | compact starter |
Design of the product | reversing starter |
Product type designation | 3RA62 |
General technical data |
Product function | |
Control circuit interface to parallel wiring | Yes |
Product extension | |
Auxiliary switch | Yes |
Insulation voltage | |
rated value | 690 V |
Degree of pollution | 3 |
Surge voltage resistance rated value | 6 000 V |
maximum permissible voltage for safe isolation | |
between main and auxiliary circuit | 400 V |
between auxiliary and auxiliary circuit | 250 V |
between control and auxiliary circuit | 300 V |
Protection class IP | IP20 |
Shock resistance | a=60 m/s2 (6g) with 10 ms per 3 shocks in all axes |
Mechanical service life (switching cycles) | |
of the main contacts typical | 10 000 000 |
of auxiliary contacts typical | 10 000 000 |
of the signaling contacts typical | 10 000 000 |
Electrical endurance (switching cycles) of auxiliary contacts | |
at DC-13 at 6 A at 24 V typical | 30 000 |
at AC-15 at 6 A at 230 V typical | 200 000 |
Type of assignment | continous operation according to IEC 60947-6-2 |
Reference code acc. to DIN EN 81346-2 | Q |
Reference code acc. to DIN EN 61346-2 | Q |
Ambient conditions |
Installation altitude at height above sea level | |
maximum | 2 000 m |
Relative humidity during operation | 10 ... 90 % |
Main circuit |
Number of poles for main current circuit | 3 |
Adjustable pick-up value current of the current-dependent overload release | 0.1 ... 0.4 A |
Formula for making capacity limit current | 120 x Ie |
Formula for interruption capacity limit current | 100 x Ie |
Mechanical power output for 4-pole AC motor | |
at 400 V rated value | 0.09 kW |
at 500 V rated value | 0.12 kW |
at 690 V rated value | 0.18 kW |
Operating voltage | |
at AC-3 rated value maximum | 690 V |
Operating current | |
at AC at 400 V rated value | 0.4 A |
at AC-43 | |
— at 400 V rated value | 0.3 A |
— at 500 V rated value | 0.32 A |
— at 690 V rated value | 0.35 A |
Operating power | |
at AC-3 | |
— at 400 V rated value | 90 W |
at AC-43 | |
— at 400 V rated value | 90 W |
— at 500 V rated value | 120 W |
— at 690 V rated value | 180 W |
No-load switching frequency | 3 600 1/h |
Operating frequency | |
at AC-41 acc. to IEC 60947-6-2 maximum | 750 1/h |
at AC-43 acc. to IEC 60947-6-2 maximum | 250 1/h |
Control circuit/ Control |
Type of voltage | AC/DC |
Control supply voltage 1 at AC | |
at 50 Hz rated value | 24 V |
at 50 Hz | 42 ... 70 V |
at 60 Hz rated value | 24 V |
at 60 Hz | 42 ... 70 V |
Control supply voltage frequency | |
1 rated value | 50 Hz |
2 rated value | 60 Hz |
Control supply voltage 1 | |
at DC | 42 ... 70 V |
Holding power | |
at AC maximum | 3.2 W |
at DC maximum | 4.2 W |
Auxiliary circuit |
Number of NC contacts for auxiliary contacts | 0 |
Number of NO contacts for auxiliary contacts | 2 |
Number of CO contacts | |
of the current-dependent overload release for signaling contact | 1 |
Operating current of auxiliary contacts at AC-12 maximum | 10 A |
Operating current of auxiliary contacts at DC-13 | |
at 250 V | 0.27 A |
Protective and monitoring functions |
Trip class | CLASS 10 and 20 adjustable |
Operational short-circuit current breaking capacity (Ics) | |
at 400 V | 53 kA |
at 500 V rated value | 3 kA |
at 690 V rated value | 3 kA |
UL/CSA ratings |
Full-load current (FLA) for three-phase AC motor | |
at 480 V rated value | 0.4 A |
at 600 V rated value | 0.4 A |
Contact rating of auxiliary contacts according to UL | contacts 21-22, 13-14, 43-44 Q600 / A600, contacts 77-78 R300 / B300, contacts 95-96-98 R300 / D300 |
Short-circuit protection |
Product function Short circuit protection | Yes |
Design of short-circuit protection | electromagnetic |
Design of the fuse link | |
for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A |
for short-circuit protection of the signaling switch of the short-circuit release required | 6A gL/gG/400V |
for short-circuit protection of the signaling switch of the overload release required | 4A gL/gG/400V |
Installation/ mounting/ dimensions |
Mounting position | any |
recommended | vertical, on horizontal standard mounting rail |
Mounting type | screw and snap-on mounting |
Height | 170 mm |
Width | 90 mm |
Depth | 165 mm |
Connections/Terminals |
Product function | |
removable terminal for main circuit | Yes |
removable terminal for auxiliary and control circuit | Yes |
Type of electrical connection | |
for main current circuit | plug-in without terminals |
for auxiliary and control current circuit | plug-in without terminals |
Safety related data |
B10 value | |
with high demand rate acc. to SN 31920 | 3 000 000 |
Proportion of dangerous failures | |
with low demand rate acc. to SN 31920 | 40 % |
with high demand rate acc. to SN 31920 | 50 % |
Failure rate [FIT] | |
with low demand rate acc. to SN 31920 | 100 FIT |
T1 value for proof test interval or service life acc. to IEC 61508 | 20 y |
Communication/ Protocol |
Product function Bus communication | No |
Protocol is supported | |
IO-Link protocol | No |
Product function Control circuit interface with IO link | No |
Electromagnetic compatibility |
Conducted interference | |
due to burst acc. to IEC 61000-4-4 | 4 kV main contacts, 2 kV auxiliary contacts |
due to conductor-earth surge acc. to IEC 61000-4-5 | 4 kV main contacts, 2 kV auxiliary contacts |
due to conductor-conductor surge acc. to IEC 61000-4-5 | 2 kV main contacts, 1 kV auxiliary contacts |
due to high-frequency radiation acc. to IEC 61000-4-6 | 0.15-80Mhz at 10V |
Field-bound parasitic coupling acc. to IEC 61000-4-3 | 10 V/m |
Electrostatic discharge acc. to IEC 61000-4-2 | 8 kV |
Conducted HF-interference emissions acc. to CISPR11 | 150 kHz ... 30 MHz Class A |
Field-bound HF-interference emission acc. to CISPR11 | 30 ... 1000 MHz Class A |
Supply voltage |
Supply voltage required Auxiliary voltage | No |